# Samples and known issues Source: [https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html](https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html) This topic discusses the issues, regardless of the sample type (or types) on which they occur. ## Sample testing Source: [https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html](https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html) See [Table : Device identification details](https://docs.qualcomm.com/doc/80-30843-1/topic/Mechanical_information.html#iqr1594375905599__table_hwg_5vl_bkb) for device identification details for all available samples. ### Engineering samples (ES) Source: [https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html](https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html) These devices undergo limited testing and sometimes have significant feature limitations. They are suitable to assist with PCB development, to conduct board-level electrical evaluation tests, and to explore manufacturing considerations. Engineering samples should not be used for product-level qualification. ### Commercial samples (CS) Source: [https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html](https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html) These devices undergo full production-level testing, and meet the specifications and features described in the data sheet, except as otherwise noted in this document. They have passed device level qualification. Commercial samples are suitable for performance testing, and also for product-level production and qualification. ## Compatible software releases Source: [https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html](https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html) Each sample type is for use with a particular QRB2210 software version (or later). Sample types are not expected to be compatible with AMSS software releases that occurred earlier than that particular version. The following table identifies the software compatibility of each sample type. Table : Software compatibility for each sample type (PRR value) | Variant | PRR | Compatible software | Comments | | --- | --- | --- | --- | | QRB2210 | 000 | QRB2210.LE.1.0-00007-STD.PROD-1 | ES software release | | QRB2210 | 000 | QRB2210.LE.1.0-00016-STD.PROD-3 | CS software release | ## Known issues Source: [https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html](https://docs.qualcomm.com/doc/80-30843-1/topic/samples-and-known-issues.html) There are no known issues for QRB2210. Last Published: Oct 08, 2025 [Previous Topic Part reliability](https://docs.qualcomm.com/bundle/publicresource/80-30843-1/topics/Part_reliability.md) [Next Topic Revision history](https://docs.qualcomm.com/bundle/publicresource/80-30843-1/topics/Revision_history.md)