# Thermal architecture
The thermal architecture shows how the Qualcomm Linux thermal framework interacts with temperature sensors (Tsens) hardware,
cooling map interfaces, and user space clients.
**Figure : Thermal architecture**
Table : Description of the components of thermal architecture
| Components of thermal architecture | Description |
| --- | --- |
| Thermal device tree |
A thermal device tree consists of various thermal zones.
A thermal zone is configured for every Tsens.
Each thermal zone consists of sensor hardware information, different levels of thermal thresholds, and their respective cooling actions.
All rules for a thermal zone are defined in the device tree.
|
| Thermal framework | The thermal framework parses the thermal zone rules from the device tree and configures Tsens hardware to generate interrupts when temperature crosses the threshold. |
| Thermal governor |
The thermal governor is a temperature monitor algorithm that controls the temperature of a thermal zone.
It mitigates the cooling devices associated with the zone and keeps the temperature within the limit.
On receiving an interrupt notification from Tsens hardware, the thermal framework uses a stepwise thermal governor to communicate the cooling actions to the cooling map interface (CPU frequency driver).
|
| Cooling map interface |
A cooling map interface is a collection of devices that can be throttled to reduce the temperature of Qualcomm Linux.
Every trip instance of the thermal zone is associated with a cooling device.
The thermal core framework aggregates all the cooling device instance requests and places the aggregated requests to the cooling device.
|
| User space clients | User space clients use the following interfaces to communicate with the thermal framework:
> > >
>
The sysfs interface is used to read the temperature > of Tsens and kernel trip information.
>
The Netlink interface gets information on Tsens > temperature notifications.
>
|
## Thermal mitigation policies
Qualcomm Linux uses in-built software and hardware mitigation policies to regulate the device’s thermal behavior.
The thermal framework applies the mitigation policies when required and
operates through the following policies:
- Monitors the thermal response of the system using on-die Tsens
- Applies mitigation based on thermal threshold limits defined in the
device tree
- Implements software throttling, hardware throttling, software shutdown,
and hardware shutdown mitigation policies to control temperature
The following tables list the temperatures at which in-built software and hardware mitigation occur.
Tab QCS6490/QCS5430
Tab IQ-9075
Tab IQ-8275
Tab IQ-615
Table: Temperature for hardware and software throttling for QCS6490/QCS5430
| Mitigation actions | CPU | NSP | GPU |
| --- | --- | --- | --- |
| Software throttling | | 110 ºC
Mitigation action: Device shutdown | | |
Note
The core idle injection functionality will be enabled in future release.
## Next steps